Product Catalog

Catalog › Pneumatics › Air preparation units (FRL)

Pneumatic FRL Units: Filter-Regulators, Lubricators and Air Preparation Sets

Two-stage (FR) and three-stage (FRL) air preparation units in 1/8"–1" sizes, filter-regulators, lubricators, precision regulators, spare bowls and FRL oil.

1,205 products20 in stock2 brandsQuote-based pricing
Air preparation units (FRL)

Air leaving a compressor carries three things: water, oil vapour and particles. Fed into a circuit untreated, they corrode valve spools, wear cylinder seals and clog silencers. The FRL group — filter, regulator, lubricator — sits at the inlet of a pneumatic circuit and deals with all three.

The unit has three stages. The filter passes the air through a cyclone chamber, collecting water droplets and coarse particles in the bottom of the bowl; the accumulated water is drained through a manual or automatic drain. The regulator reduces the variable line pressure to the fixed value the circuit needs and holds it there; the small gauge on top shows the setting. The lubricator adds a controlled mist of oil to the air, lubricating the internal surfaces of valves and cylinders.

Not every circuit needs all three stages. The filter + regulator pair (FR) is the most common arrangement, and most modern cylinders are lubricated for life and run without a lubricator. A lubricator is added for older cylinders, high cycle rates and percussive hand tools. Once lubrication has been started it should not be stopped: the oil washes away the factory grease, and if lubrication ceases the component runs dry.

Selection turns on two values. Port size (1/4", 3/8", 1/2", 1") is set by the flow in the line; a unit sized below the line acts as a restriction, causing a pressure drop and slowing the cylinders. Body type is chosen for the environment: a plastic bowl is economical but cracks where solvent vapours are present, so metal-bodied units are used in those conditions.

Alongside complete units, this group also carries spare bowls, regulator gauges and FRL oil — including food-grade oil for food plants. For the rest of the circuit see the «Pneumatic Valves» and «Pneumatic Cylinders» pages.

Brands and series

Systematic 29 products

Series pages are in Turkish; product codes are the same in every language.

Other products (brand not specified)

1,084 products in our price lists with no brand or no code stated, sorted by name (in Turkish). Pages: 3.

Brands and standards in stock

1/8" – 1" port sizesTwo-stage (FR) and three-stage (FRL) setsManual and automatic drainPrecision regulators 0.5–8 barMetal and plastic bodiesFesto and SMC type equivalentsFRL oil (food-grade available)

Manufacturer part numbers

These products are searched for in the field by the manufacturer's part number, not by our stock code. The code follows this pattern: TİP + HORTUM ÖLÇÜSÜ + DİŞ — for example AC901-15. Every code in the lists below can be supplied; some are held in stock ready to ship.

Filtreli regülatör

Filter regulator. Every code listed can be supplied. The manufacturer's catalogue lists 14 codes in this series; all can be supplied.

14 codes

AC901-15AC901-20AF-40/50AFC2000BFC4000AC4010-04AF2000-02AF3000-02AF3000-03AF4000-04AF5000-10AF-20AF-30AF-50

Regülatör

Regulator. Every code listed can be supplied. The manufacturer's catalogue lists 49 codes in this series; all can be supplied.

49 codes

AW2000-02AW3000-02AW3000-03AW4000-04AW5000-10AF-20AF-30AF-40/50AFR900-15AFR900-20AFR2000BFR4000DR100-M5DR100-01QTYH-08QTYH-15QTYH-20QTYH-25QTYd-15QTYd-20QTYd-25QTYd-40QTYd-50QTY-25QTY-40QTY-50AR900-15AR900-20ITV205-312SIR1000-01IR1010-01IR1020-01IR2000-02IR2020-02IR3000-04IR3020-04HAR825-14HAR925-20XR4-02-1XR4-02-2NAR200-01NAR200-02AR2000-02AR3000-02AR3000-03AR4000-04AR5000-10AR2000BR4000

Yağlayıcı

Lubricator. Every code listed can be supplied. The manufacturer's catalogue lists 14 codes in this series; all can be supplied.

14 codes

AL2000-02AL3000-02AL3000-03AL4000-04AL5000-10AL2000BL4000QIUd-20QIUd-25QIUd-40QIUd-50QIU-20QIU-40QIU-50

The codes listed are the manufacturer's own part numbers. For sizes not held in stock, ask for the lead time — supply is quick because we carry the series. Prices are given on quotation.

Manufacturer part numbers

These products are searched for in the field by the manufacturer's part number, not by our stock code. The code follows this pattern: SERİ + VARYANT — for example ZDB6 VP1. Every code in the lists below can be supplied; some are held in stock ready to ship.

KPC

FRL unit and silencer The manufacturer's catalogue lists 25 codes in this series; all can be supplied.

25 codes

KPC03-M5KPC04-G01KPC04-G02KPC04-M5KPC04-M6KPC06-G01KPC06-G02KPC06-G03KPC06-G04KPC06-M5KPC06-M6KPC08-G01KPC08-G02KPC08-G03KPC08-G04KPC10-G01KPC10-G02KPC10-G03KPC10-G04KPC12-G01KPC12-G02KPC12-G03KPC12-G04KPC16-G03KPC16-G04

KPL

FRL unit and silencer The manufacturer's catalogue lists 25 codes in this series; all can be supplied.

25 codes

KPL03-M5KPL04-G01KPL04-G02KPL04-M5KPL04-M6KPL06-G01KPL06-G02KPL06-G03KPL06-G04KPL06-M5KPL06-M6KPL08-G01KPL08-G02KPL08-G03KPL08-G04KPL10-G01KPL10-G02KPL10-G03KPL10-G04KPL12-G01KPL12-G02KPL12-G03KPL12-G04KPL16-G03KPL16-G04

A

FRL unit and silencer The manufacturer's catalogue lists 11 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2, 2

11 codes

A-06A-08A-10A-15A-20A-25A-32A-40A-50A-M5A300

KPCF

FRL unit and silencer The manufacturer's catalogue lists 11 codes in this series; all can be supplied.

11 codes

KPCF06-G01KPCF06-G02KPCF06-G03KPCF06-G04KPCF08-G01KPCF08-G02KPCF08-G03KPCF08-G04KPCF10-G01KPCF10-G02KPCF10-G03

KPB

FRL unit and silencer The manufacturer's catalogue lists 8 codes in this series; all can be supplied.

8 codes

KPB06-G01KPB06-G02KPB06-G03KPB06-G04KPB06-M5KPB08-G01KPB08-G02KPB08-G03

EL

FRL unit and silencer The manufacturer's catalogue lists 7 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 1/2, 3/4, 1

7 codes

EL2000-01EL2010-02EL3010-03EL4010-04EL5010-06EL5010-10EL804-02

FER

FRL unit and silencer The manufacturer's catalogue lists 7 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 1/2, 3/4, 1

7 codes

FER 1 MAXIFER 1/2 MIDIFER 1/4 MIDIFER 1/4 MINIFER 1/8 MINIFER 3/4 MAXIFER 3/8 MIDI

V

FRL unit and silencer The manufacturer's catalogue lists 7 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 1/2, 3/4, 1

7 codes

V-06V-08V-10V-15V-20V-25V-M5

EC

FRL unit and silencer The manufacturer's catalogue lists 6 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 1/2, 3/4, 1

6 codes

EC2010-01EC2010-02EC3010-03EC4010-04EC5010-06EC5010-10

FEC

FRL unit and silencer The manufacturer's catalogue lists 6 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 3/4, 1

6 codes

FECFECFECFECFEC 1" MAXIFEC 3/4" MAXI

SD

FRL unit and silencer The manufacturer's catalogue lists 6 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 1/2, 3/4, 1

6 codes

SD-06SD-08SD-10SD-15SD-20SD-25

SU

FRL unit and silencer The manufacturer's catalogue lists 6 codes in this series; all can be supplied.

thread (inch)1/8, 1/4, 3/8, 1/2, 3/4, 1

6 codes

SU-06SU-08SU-10SU-15SU-20SU-25

The codes listed are the manufacturer's own part numbers. For sizes not held in stock, ask for the lead time — supply is quick because we carry the series. Prices are given on quotation.

Frequently asked questions

Should I buy a two-stage or a three-stage unit?

The two-stage arrangement (filter + regulator) is today's standard choice; most modern pneumatic cylinders and valves are lubricated for life and need no oil. The three-stage arrangement (filter + regulator + lubricator) is needed for older cylinders, high-cycle machines and percussive hand tools.

Can lubrication be stopped once it has been started?

It should not be. Oil carried in the air gradually washes away the permanent grease applied at the factory. If lubrication then ceases, the surfaces run dry and wear accelerates. Once a circuit has been run lubricated, it should stay lubricated for the rest of its life.

How is FRL size selected?

Port size follows the line diameter and the air flow consumed. Undersizing the unit is the most common mistake: it behaves as a restriction, pressure drops, and the cylinders run slower than expected. When in doubt, going one size up is the safe choice.

Water keeps collecting in the filter bowl — is that normal?

Yes, that is exactly what the filter is for — moisture in the compressed air condenses as it cools. What matters is draining it. Manual-drain bowls should be emptied at the start of each shift; where that is likely to be forgotten, choose an automatic-drain type. Once the bowl overfills, water passes into the circuit.

The regulator will not hold the set pressure — what should I check?

Check the inlet pressure first: a regulator cannot produce an outlet pressure higher than its inlet, and needs at least 1 bar of difference. If the inlet is adequate, the diaphragm may be torn or the spring housing fouled. If the adjusting knob is not locked after setting, vibration will turn it and drift the pressure.

Get a quote for Air preparation units (FRL)

Send us the size and quantity you need and our sales team will get back to you the same day with pricing and lead time. If you're not sure of the size, a photo of the part you have is enough.

More in Pneumatics